Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; : e2303272, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38412280

RESUMO

Atopic dermatitis (AD), a prevalent skin condition often complicated by microbial infection, poses a significant challenge in identifying the responsible pathogen for its effective management. However, a reliable, safe tool for pinpointing the source of these infections remains elusive. In this study, a novel on-site pathogen detection that combines chemically functionalized nanotopology with genetic analysis is proposed to capture and analyze pathogens closely associated with severe atopic dermatitis. The chemically functionalized nanotopology features a 3D hierarchical nanopillar array (HNA) with a functional polymer coating, tailored to isolate target pathogens from infected skin. This innovative nanotopology demonstrates superior pathogenic capture efficiency, favorable entrapment patterns, and non-cytotoxicity. An HNA-assembled stick is utilized to directly retrieve bacteria from infected skin samples, followed by extraction-free quantitative loop-mediated isothermal amplification (direct qLAMP) for validation. To mimic human skin conditions, porcine skin is employed to successfully capture Staphylococcus aureus, a common bacterium exacerbating AD cases. The on-site detection method exhibits an impressive detection limit of 103 cells mL-1 . The HNA-assembled stick represents a promising tool for on-site detection of bacteria associated with atopic dermatitis. This innovative approach enables to deepen the understanding of AD pathogenesis and open avenues for more effective management strategies for chronic skin conditions.

2.
ACS Nano ; 17(7): 6507-6518, 2023 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-36971140

RESUMO

Point-of-care real-time reverse-transcription polymerase chain reaction (RT-PCR) facilitates the widespread use of rapid, accurate, and cost-effective near-patient testing that is available to the public. Here, we report ultrafast plasmonic nucleic acid amplification and real-time quantification for decentralized molecular diagnostics. The plasmonic real-time RT-PCR system features an ultrafast plasmonic thermocycler (PTC), a disposable plastic-on-metal (PoM) cartridge, and an ultrathin microlens array fluorescence (MAF) microscope. The PTC provides ultrafast photothermal cycling under white-light-emitting diode illumination and precise temperature monitoring with an integrated resistance temperature detector. The PoM thin film cartridge allows rapid heat transfer as well as complete light blocking from the photothermal excitation source, resulting in real-time and highly efficient PCR quantification. Besides, the MAF microscope exhibits close-up and high-contrast fluorescence microscopic imaging. All of the systems were fully packaged in a palm size for point-of-care testing. The real-time RT-PCR system demonstrates the rapid diagnosis of coronavirus disease-19 RNA virus within 10 min and yields 95.6% of amplification efficiency, 96.6% of classification accuracy for preoperational test, and 91% of total percent agreement for clinical diagnostic test. The ultrafast and compact PCR system can decentralize point-of-care molecular diagnostic testing in primary care and developing countries.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , Patologia Molecular , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , RNA Viral , Teste para COVID-19
3.
Biosensors (Basel) ; 13(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36671871

RESUMO

Surface functionalization and bioreceptor immobilization are critical processes in developing a highly sensitive and selective biosensor. The silanization process with 3-aminopropyltriethoxysilane (APTES) on oxide surfaces is frequently used for surface functionalization because of beneficial characteristics such as its bifunctional nature and low cost. Optimizing the deposition process of the APTES layer to obtain a monolayer is crucial to having a stable surface and effectively immobilizing the bioreceptors, which leads to the improved repeatability and sensitivity of the biosensor. This review provides an overview of APTES deposition methods, categorized into the solution-phase and vapor-phase, and a comprehensive summary and guide for creating stable APTES monolayers on oxide surfaces for biosensing applications. A brief explanation of APTES is introduced, and the APTES deposition methods with their pre/post-treatments and characterization results are discussed. Lastly, APTES deposition methods on nanoparticles used for biosensors are briefly described.


Assuntos
Técnicas Biossensoriais , Óxidos , Propriedades de Superfície , Silanos , Propilaminas , Gases , Técnicas Biossensoriais/métodos
4.
Biosensors (Basel) ; 11(1)2020 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-33374119

RESUMO

An optical cavity-based biosensor (OCB) has been developed for point-of-care (POC) applications. This label-free biosensor employs low-cost components and simple fabrication processes to lower the overall cost while achieving high sensitivity using a differential detection method. To experimentally demonstrate its limit of detection (LOD), we conducted biosensing experiments with streptavidin and C-reactive protein (CRP). The optical cavity structure was optimized further for better sensitivity and easier fluid control. We utilized the polymer swelling property to fine-tune the optical cavity width, which significantly improved the success rate to produce measurable samples. Four different concentrations of streptavidin were tested in triplicate, and the LOD of the OCB was determined to be 1.35 nM. The OCB also successfully detected three different concentrations of human CRP using biotinylated CRP antibody. The LOD for CRP detection was 377 pM. All measurements were done using a small sample volume of 15 µL within 30 min. By reducing the sensing area, improving the functionalization and passivation processes, and increasing the sample volume, the LOD of the OCB are estimated to be reduced further to the femto-molar range. Overall, the demonstrated capability of the OCB in the present work shows great potential to be used as a promising POC biosensor.


Assuntos
Técnicas Biossensoriais , Proteína C-Reativa , Estreptavidina , Anticorpos , Técnicas Biossensoriais/economia , Humanos
5.
Sensors (Basel) ; 20(20)2020 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-33086566

RESUMO

The demand for biosensor technology has grown drastically over the last few decades, mainly in disease diagnosis, drug development, and environmental health and safety. Optical resonator-based biosensors have been widely exploited to achieve highly sensitive, rapid, and label-free detection of biological analytes. The advancements in microfluidic and micro/nanofabrication technologies allow them to be miniaturized and simultaneously detect various analytes in a small sample volume. By virtue of these advantages and advancements, the optical resonator-based biosensor is considered a promising platform not only for general medical diagnostics but also for point-of-care applications. This review aims to provide an overview of recent progresses in label-free optical resonator-based biosensors published mostly over the last 5 years. We categorized them into Fabry-Perot interferometer-based and whispering gallery mode-based biosensors. The principles behind each biosensor are concisely introduced, and recent progresses in configurations, materials, test setup, and light confinement methods are described. Finally, the current challenges and future research topics of the optical resonator-based biosensor are discussed.


Assuntos
Técnicas Biossensoriais , Sistemas Automatizados de Assistência Junto ao Leito
6.
Sensors (Basel) ; 19(9)2019 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-31083614

RESUMO

An optical cavity-based sensor using a differential detection method has been proposed for point-of-care diagnostics. We developed a low-cost and portable optical cavity-based sensor system using a 3D printer and off-the-shelf optical components. In this paper, we demonstrate the sensing capability of the portable system through refractive index measurements. Fabricated optical cavity samples were tested using the portable system and compared to simulation results. A referencing technique and digital low pass filtering were applied to reduce the noise of the portable system. The measurement results match the simulation results well and show the improved linearity and sensitivity by employing the differential detection method. The limit of detection achieved was 1.73 × 10-5 Refractive Index Unit (RIU), which is comparable to other methods for refractive index sensing.


Assuntos
Técnicas Biossensoriais/economia , Técnicas Biossensoriais/métodos , Desenho de Equipamento/métodos , Fibras Ópticas , Refratometria/métodos
7.
Opt Express ; 26(15): 18982-18989, 2018 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-30114158

RESUMO

We have developed a low-cost optical cavity-based biosensor with a differential detection method for point-of-care medical diagnostics. To experimentally demonstrate its label-free real-time biosensing capability, we performed the detection of biotinylated bovine serum albumin (BSA). Streptavidin is introduced into the optical cavity structure and immobilized on 3-aminopropyltriethoxysilane (APTES) coated surface. After rinsing out unbound streptavidin with DI water, biotinylated BSA without any labeling is introduced. A CMOS camera captures the transmitted light of two different wavelengths passing through the optical cavity sensing area in real-time. Then, the differential values are calculated to enhance the responsivity. We successfully demonstrated the label-free real-time detection of biotinylated BSA, and the measurement results matched well with the simulation results. The limit of detection of the optical cavity-based biosensor for the biotinylated BSA detection with the sensing area of 180 µm × 180 µm is estimated to be 2.82 pM, which could be reduced further for a smaller sensing area with the tradeoff of a longer sensing time.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoglobulina G/análise , Soroalbumina Bovina/análise , Animais , Anticorpos/análise , Técnicas Biossensoriais/economia , Biotinilação , Bovinos , Estreptavidina/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...